Other Life Sciences

Bioimpedance

Bioimpedance records the parameters associated with impedance cardiography, cardiac output measurements, thoracic impedance changes as a function of respiration or any kind of biological impedance monitoring. A separate set of monitoring electrodes measures the voltage developed across the tissue volume.

Applications:


Tissue Engineering
Cell Culture Monitoring
Real-time monitoring of muscle stem cell


Airflow Transducer

We offer a full assortment of airflow transducers that can be used to perform a wide variety of high performance tests relating to air flow, lung volume, and expired gas analysis. It can be used with data analysis and acquisition hardware platforms, amplifiers and other system components, this amplifier is an element of a complete data acquisition and analysis system.


Applications:


Measurement of respiratory gas concentrations.
In pulmonary function and exercise physiology
In investigating breathing mechanics



Differential Pressure Transducer

Differential pressure transducers are used for low range pressure monitoring. The related differential pressure ports are generally located on the front of the transducers and are easily connected to breathing circuits, pneumotachs or plethysmography boxes. The transducers plug directly into the DA100C general-purpose differential amplifier and are extremely sensitive.


Applications:


Lung Volume Analysis
Expired Gas Analysis
Accurate Airflow Measurement
Temperature & Pressure Measurement



Gait Analysis

It acquires up to 16 channels of gait-specific data, including heel-toe, goniometry, accelerometry and more. One setup might incorporate two channels for heel/toe strike timing, ten channels for EMG signals and four channels of goniometry data. Its logging mode allows the subject to wear devices outside the lab and record continuously for many hours.

Applications:


Quantification of Joint Kinematics
In Orthotic & Prosthetic Clinics
In Musculoskeletal abnormality
Cardiovascular Health Issues



O2 Measurement Amplifier

The O2100C is a paramagnetic-based oxygen measurement module designed to provide accurate measurement of the oxygen content in ambient air, expired breath, ventilator circuits, and in breathing gas mixtures. The paramagnetic technology is non-depleting, which means there are no consumable parts, ensure consistent performance over time.

Features:


The module provides a selectable range of analog outputs that map voltages to 0-100% oxygen concentration levels.
The module is a lightweight, rugged unit that offers a number of advanced features, such as fast response.
The excellent linearity of O2100C makes it possible to calibrate the module by checking two optimally separated points.



Co2 Measurement Amplifier

The CO2100C is an infrared-based carbon dioxide measurement module designed to provide accurate measurement of the carbon dioxide content in ambient air, expired breath, and in breathing gas mixtures in the desired measurement range. The CO2100C is calibrated to measure carbon dioxide in the range 0 to 10%.

Features


The module provides a selectable range of analog outputs that map voltages to 0-100% oxygen concentration levels.
The module is a lightweight, rugged unit that offers a number of advanced features, such as fast response.
The excellent linearity of O2100C makes it possible to calibrate the module by checking two optimally separated points.



Other Biopotentials



Blood Gases
Electrocardiography
Electrodermal Activity
Electroencephalography
Electrogastrography
Electromyography
Electrooculography and Eye Movement
Evoked Response
Hemodynamics
Imaging
Impedance Cardiography and Noninvasive Cardiac Output
Metabolic Activity
Movement
Neuromarketing
Plethysmography
Polysomnography
Respiratory Activity
Stimulation
Temperature